This data includes results on an analysis of existing and projected energy, cost, and carbon for the City of Ann Arbor - District Geothermal Design and Deployment to Equitably Decarbonize Low Income Neighborhoods in Ann Arbor project. The scope of the project includes designing and implementing a geothermal district heating and cooling system that reduces thermal heating and cooling load by 75% and greenhouse gas emissions by 40% in the project area (262 households, 6 commercial buildings). The existing neighborhood was modeled using Design Builder, an EnergyPlus software, to understand the current energy load. The energy model was then flipped to reflect the designed district geothermal heating and cooling system to project the effect on energy, carbon, and cost. This dataset includes the analysis files utilized and created for this study. There are 3 categories of data: 1) existing/benchmarking, 2) energy modeling, and 3) post processed calculations. This follows the methodology and process of the project team, which is fully explained in file 00_Technical Economic Environmental Assessment. All uses of data are referenced throughout this assessment to their respective files included below.
05_NREL Timeseries Data.xlsx
XLSX04_NREL ResStock Energy Data.xlsx
XLSX06_DOE Prototype Building.PDF
PDF07_Home - Best - Existing EM Analysis.drs
drs08_Home - Middle - Existing EM Analysis.drs
drs12_Home - Worst - Geo EM Analysis.drs
drs10_Home - Best - Geo EM Analysis.drs
drs09_Home - Worst - Existing EM Analysis.drs
drs11_Home - Middle - Geo EM Analysis.drs
drs13_Home - Best - Wx EM Analysis.drs
drs14_Home - Middle - Wx EM Analysis.drs
drs15_Home - Worst - Wx EM Analysis.drs
drs16_262 Homes TMY3 - Existing EM Analysis.drs
drs26_262 Homes TMY3 - Pump Energy.drs
drs17_262 Homes TMY3 - Geo EM Analysis.drs
drs19_Community Center - TMY - Geo EM Analysis.drs
drs18_Community Center - TMY - Existing EM Analysis.drs
drs22_County Health TMY - Existing EM Analysis.drs
drs21_Bryant Elementary - TMY - Geo EM Analysis.drs
drs20_Bryant Elementary - TMY - Existing EM Analysis.drs
drs25_Wheeler Vehicle Storage - TMY - Existing EM Analysis.drs
drs24_Wheeler Maintenance - TMY - Existing EM Analysis.drs
drs23_Wheeler Center Operations - TMY - Existing EM Analysis.drs
drs03_Commercial Building Existing Data Assembled.xlsx
XLSX28_700ft 180 holes Ground Loop Design Report.pdf
PDF27_500ft 260 holes Ground Loop Design Report.pdf
PDF02_UTILITY Bryant Neighborhood Data - Electric and Gas.xlsx
XLSX01_ELEVATE Aggregate Energy Audit Data.xlsx
XLSX30_Carbon Projection Analysis.xlsx
XLSX29_Energy Model Analysis - All Buildings.xlsx
XLSX00_Technical Economic Environmental Assessment.pdf
PDF