This dataset contains materials from the Coalition for Community-Supported Affordable Geothermal Energy Systems (C2SAGES) project, which evaluated the techno-economic feasibility of a community geothermal system for a residential development in Hinesburg, VT. The dataset includes detailed soil conductivity test reports, energy models, borehole design reports, hourly energy loads for heating, cooling, and hot water, and design layouts. EnergyPlus was used to model building energy loads, and Modelica software was applied for geothermal loop sizing based on these loads and soil conductivity results. Python scripts for network design further refined the models. Key files include PDF reports on borehole design (with projections for 1-year, 15-year, and 30-year systems), soil conductivity test results, EnergyPlus modeling outputs, and 2D/3D design drawings in PDF, DWG, and DXF formats. Python notebooks for network design and OnePipe model files are also provided, with Modelica required for viewing certain files. Outputs and modeling data are in various formats including CSV, JPG, HTML, and IDF, with units and data clearly labeled to support understanding of system design and performance for the proposed geothermal solution.
Soil Conductivity Test Report - 12-29-2023.pdf
PDFSoil Conductivity Test Report - 06-12-2024.pdf
PDFWindy Ridge Phase 1 - Proposed Geothermal before GHX sizing.idf
idfWindy Ridge Phase 1 - Baseline.idf
idfWindy Ridge Phase 1 - Proposed Geothermal.idf
idfWindy Ridge Phase 2 Baseline.idf
idfWindy Ridge Phase 2 Proposed Geothermal.idf
idfTopology of Project Site.dwg
dwgProposed Project Plan.dwg
dwgLeft Elevation.pdf
PDFGround Floor Plan.pdf
PDFRight Elevation.pdf
PDFRear Elevation.pdf
PDFFirst Floor Plan.pdf
PDFSecond Floor Plan.pdf
PDFSingle Family Housing Floor Plan.pdf
PDFFront Elevation.pdf
PDFSterling Homes Floor Plan.pdf
PDFAxonometric View of the Proposed Project Plan.jpg
JPEGRight View of the Proposed Project Plan.jpg
JPEGTop View of the Proposed Project Plan.jpg
JPEGIsometric View of the Sterling Homes.jpg
JPEGBack View of the Proposed Project Plan.jpg
JPEGLeft View of the Proposed Project Plan.jpg
JPEGFront View of the Proposed Project Plan.jpg
JPEGIsometric View of the North Meadow Homes.jpg
JPEGBorehole design report - 30 year monthly method.pdf
PDFBorehole design report - 1 year hourly method.pdf
PDFBorehole design report - 15 year hourly method.pdf
PDFBorehole design report - Summary.pdf
PDFEnergyPlus Output - Phase 1 Proposed Geothermal.htm
HTMLEnergyPlus Output - Phase 1 Baseline.htm
HTMLHourly Space Conditioning Loads - Phase 1 - 6 Town House Units.csv
CSVHourly Space Conditioning Loads - Phase 1 - Proposed Project.csv
CSVHourly Space Conditioning Loads - Phase 1 - Mixed unit buildings.csv
CSVHourly Space Conditioning Loads - Phase 1 - Private Townhouse Units.csv
CSVHourly Space Conditioning Loads - Phase 1 - 1 Bedroom Multifamily Building.csv
CSVHourly Space Conditioning Loads - Phase 1 - 8 Townhouse Unit Buildings.csv
CSVHourly DHW Loads - Proposed Project.csv
CSVEnergyPlus Output - Phase 2 Baseline - Gas and Water Tariff.htm
HTMLEnergyPlus Output - Phase 2 - Proposed Geothermal - 5 electric meters.htm
HTMLEnergyPlus Output - Phase 2 - Proposed Geothermal - Water Meter.htm
HTMLEnergyPlus Output - Phase 2 - Baseline - 5 electric meters.htm
HTMLHourly Space Conditioning Loads - Phase 2 - Proposed Project.csv
CSVHourly Space Conditioning Loads - Proposed Project - Phase 2 - Daycare.csv
CSVHourly Space Conditioning Loads - Proposed Project - Phase 2 - Sterling Homes.csv
CSVHourly Space Conditioning Loads - Proposed Project - Phase 2 - Champlaign Housing Trust.csv
CSVEnergyPlus File - GHX Sizing - Phase 1.idf
idfEnergyPlus File - GHX Sizing - Phase 2.idf
idfBorehole Loads with and without DHW - Phase 1.xlsx
XLSXBorehole Temperatures with DHW - Phase 1.xlsx
XLSXPipe Layout Combined Phase 1 and 2.xlsx
XLSXOnePipe Model - Phase 1.zip
ZIPGHX Network Design - Python Notebooks - Phase 1 2.zip
ZIPBorehole Temperatures with DHW Phase 2.xlsx
XLSXBorehole Loads for Phase 1 and Phase 2.xlsx
XLSX