Open Net Zero logo
Community Geothermal: Soil Conductivity, Borehole Design, Energy Models, and Load Data for a Residential System Development - Hinesburg, VT
L o a d i n g
Organization
National Renewable Energy Laboratory (NREL) - view all
Update frequencyunknown
Last updated4 days ago
Overview

This dataset contains materials from the Coalition for Community-Supported Affordable Geothermal Energy Systems (C2SAGES) project, which evaluated the techno-economic feasibility of a community geothermal system for a residential development in Hinesburg, VT. The dataset includes detailed soil conductivity test reports, energy models, borehole design reports, hourly energy loads for heating, cooling, and hot water, and design layouts. EnergyPlus was used to model building energy loads, and Modelica software was applied for geothermal loop sizing based on these loads and soil conductivity results. Python scripts for network design further refined the models. Key files include PDF reports on borehole design (with projections for 1-year, 15-year, and 30-year systems), soil conductivity test results, EnergyPlus modeling outputs, and 2D/3D design drawings in PDF, DWG, and DXF formats. Python notebooks for network design and OnePipe model files are also provided, with Modelica required for viewing certain files. Outputs and modeling data are in various formats including CSV, JPG, HTML, and IDF, with units and data clearly labeled to support understanding of system design and performance for the proposed geothermal solution.

EnergyPlusHinesburgModelicaOnePipePythonVermontborehole designborehole testingbuilding energy modelingcommGeocommunity engagementcommunity geothermaldevelopmentenergyenergy modelgeothermalgeothermal heat pumpgeothermal loop sizinggeothermal network designgeothermal sizingground heat exchangerhourly energy loadsmodelingreportsizingsystem designthermal conductivity testworkforce development
Additional Information
KeyValue
Dcat Issued2024-08-30T06:00:00Z
Dcat Modified2024-09-24T22:50:30Z
Dcat Publisher NameGTI Energy
Guidhttps://data.openei.org/submissions/7732
Harvest Object Id7b363be8-6c5a-4a3d-b0c9-db76356a1049
Harvest Source Id4eb7107f-a2b1-40e3-b36a-8161aa98a56e
Harvest Source TitleOpenEI Data Portal
Share this Dataset
Trust Signals
Trust Framework(s)None
Assuranceunknown
Data Sensitivity Classunknown
Licenceunknown
Files
  • Soil Conductivity Test Report - 12-29-2023.pdf

  • Soil Conductivity Test Report - 06-12-2024.pdf

  • Windy Ridge Phase 1 - Proposed Geothermal before GHX sizing.idf

  • Windy Ridge Phase 1 - Baseline.idf

  • Windy Ridge Phase 1 - Proposed Geothermal.idf

  • Windy Ridge Phase 2 Baseline.idf

  • Windy Ridge Phase 2 Proposed Geothermal.idf

  • Topology of Project Site.dwg

  • Proposed Project Plan.dwg

  • Left Elevation.pdf

  • Ground Floor Plan.pdf

  • Right Elevation.pdf

  • Rear Elevation.pdf

  • First Floor Plan.pdf

  • Second Floor Plan.pdf

  • Single Family Housing Floor Plan.pdf

  • Front Elevation.pdf

  • Sterling Homes Floor Plan.pdf

  • Axonometric View of the Proposed Project Plan.jpg

  • Right View of the Proposed Project Plan.jpg

  • Top View of the Proposed Project Plan.jpg

  • Isometric View of the Sterling Homes.jpg

  • Back View of the Proposed Project Plan.jpg

  • Left View of the Proposed Project Plan.jpg

  • Front View of the Proposed Project Plan.jpg

  • Isometric View of the North Meadow Homes.jpg

  • Borehole design report - 30 year monthly method.pdf

  • Borehole design report - 1 year hourly method.pdf

  • Borehole design report - 15 year hourly method.pdf

  • Borehole design report - Summary.pdf

  • EnergyPlus Output - Phase 1 Proposed Geothermal.htm

  • EnergyPlus Output - Phase 1 Baseline.htm

  • Hourly Space Conditioning Loads - Phase 1 - 6 Town House Units.csv

  • Hourly Space Conditioning Loads - Phase 1 - Proposed Project.csv

  • Hourly Space Conditioning Loads - Phase 1 - Mixed unit buildings.csv

  • Hourly Space Conditioning Loads - Phase 1 - Private Townhouse Units.csv

  • Hourly Space Conditioning Loads - Phase 1 - 1 Bedroom Multifamily Building.csv

  • Hourly Space Conditioning Loads - Phase 1 - 8 Townhouse Unit Buildings.csv

  • Hourly DHW Loads - Proposed Project.csv

  • EnergyPlus Output - Phase 2 Baseline - Gas and Water Tariff.htm

  • EnergyPlus Output - Phase 2 - Proposed Geothermal - 5 electric meters.htm

  • EnergyPlus Output - Phase 2 - Proposed Geothermal - Water Meter.htm

  • EnergyPlus Output - Phase 2 - Baseline - 5 electric meters.htm

  • Hourly Space Conditioning Loads - Phase 2 - Proposed Project.csv

  • Hourly Space Conditioning Loads - Proposed Project - Phase 2 - Daycare.csv

  • Hourly Space Conditioning Loads - Proposed Project - Phase 2 - Sterling Homes.csv

  • Hourly Space Conditioning Loads - Proposed Project - Phase 2 - Champlaign Housing Trust.csv

  • EnergyPlus File - GHX Sizing - Phase 1.idf

  • EnergyPlus File - GHX Sizing - Phase 2.idf

  • Borehole Loads with and without DHW - Phase 1.xlsx

  • Borehole Temperatures with DHW - Phase 1.xlsx

  • Pipe Layout Combined Phase 1 and 2.xlsx

  • OnePipe Model - Phase 1.zip

  • GHX Network Design - Python Notebooks - Phase 1 2.zip

  • Borehole Temperatures with DHW Phase 2.xlsx

  • Borehole Loads for Phase 1 and Phase 2.xlsx