The objective of this field test is to validate several technologies for non-invasive well integrity assessment using existing wells with a known completion. The tests were made at the Cymric oil field, which is a steam flood operation. The wells therefore undergo similar downhole conditions as geothermal wells. The Cymric field is mainly a cyclic steam operation where wells are 1000-15-00 ft in depth and the reservoir occupies the bottom 400ft. The maximum temperatures can exceed 500 degrees F and the well spacing is very close, often less than 50m. The field plan consisted of applying the Time Domain Reflectometry (TDR) method to the wells. The input voltages were set as 70 V shows the TDR responses at frequencies of 450 kHz, 2500 kHz, and 4500 kHz. There is a summary report will full information about the field tests.
OwnerNational Renewable Energy Laboratory (NREL) - view all
Update frequencyunknown
Last updatedover 1 year ago
OverviewCymricEMKern CountyTDRWISE-CASINGassessmentboreholecasingcorrosiondataelectromagneticenergyexperimentfieldfield testgeophysicsgeothermalhigh frequencyinput pulse frequencyintegrityoilsensingsteam floodsyclic steamtime domain reflectormetrywellwellborewells
Additional Information
KeyValue
dcat_issued2019-02-21T07:00:00Z
dcat_modified2020-01-27T22:38:57Z
dcat_publisher_nameLawrence Berkeley National Laboratory
guidhttps://data.openei.org/submissions/3816
ib1_trust_framework[]
language